- Home
- Industrial pumps
- Pumps by manufacturer
- WILOWilo-Drain TSW stainless steel submersible pumpWilo-Drain TMW submersible pump for drainage water drainagePB booster pumpMVI vertical high pressure pumps HELIX FIRST, MVIHorizontal high pressure pumps MEDANA, MHIWell pumps Wilo-Sub TWI 5, TWI 5-SE, TWI 5-SE PNPWILO CronoNorm NL cantilever pumpsWilo-DrainLift KH, TMP Pressure plants for wastewater disposalPumping station Wilo-Jet HWJ with a hydraulic accuHigh pressure glandless pumps MVISSubmersible pumps Wilo-Drain MTS for wastewater diSelf-priming centrifugal pumps Wilo-Jet WJFire extinguishing system Wilo-SiFire ENSpecial IPH pumps for superheated water and thermal oilWilo-FLA-2 pressure boosting systemSewage pumps Wilo EMU FAWILO TOP-S Glandless Circulation PumpsCirculation pumps for heating systems and underflo
- Horizontal high pressure pumps MEDANA, MHI
Horizontal high pressure pumps MEDANA, MHI

Appointment
High pressure pumps WILO MHI are used for pumping drinking water, cold and hot water in heat and water supply systems, condensate, a mixture of water with glycol (up to 40% glycol in the mixture), as well as other media free of mineral fats, abrasive and long-fibred inclusions.
Application of high pressure pumps MHI: installation of water supply and raising pressure, boiler feed, industrial circulation systems, water cooling circuits, fire extinguishing systems, as well as washing and irrigation installations.
Diagram productivity
Designation
Example:MHI 205N-1/E/3-400-50-2 | |
MHI |
Horizontal multistage high-pressure centrifugal pump |
2 | Consumption in m³/h |
05 | Number of impellers |
N | IE2 motor |
1 | Material 1=1.4301 (AISI 304) 2=1.4404 (AISI 316L) |
E | Sealing type E=EPDM V=FKM (Viton) |
3 | 1=1 ~ (single phase current) 3=3 ~ (three-phase current) |
400 | Connectable voltage in V |
50 | Frequency in Hz |
2 | Number of poles |
Pumps increasing pressure series MHI
Model | Power, kWt | Feed, m³/hour | Head, m | Picture |
MHI 202 | 0.55 | 5 | 25 | |
MHI 203 | 0.55 | 5 | 35 | |
MHI 204 | 0.55 | 5 | 45 | |
MHI 205 | 0.75 | 5 | 55 | |
MHI 206 | 1.1 | 5 | 65 | |
MHI 402 | 0.55 | 8 | 25 | |
MHI 403 | 0.55 | 8 | 35 | |
MHI 404 | 0.75 | 8 | 45 | |
MHI 405 | 1.1 | 8 | 55 | |
MHI 406 | 1.5 | 8 | 70 | |
MHI 802 | 0.75 | 12 | 25 | |
MHI 803 | 1.1 | 12 | 35 | |
MHI 804 | 1.5 | 12 | 45 | |
MHI 805 | 1.85 | 12 | 60 | |
MHI 1602 | 1.5 | 25 | 25 | |
MHI 1603 | 1.85 | 25 | 35 | |
MHI 1604 | 2.5 | 25 | 45 |
Technical data
WILO MHI | ||||
2 ... | 4... | 8... | 16... | |
Permissible pumped liquids | ||||
Potable and industrial water, water systems heating | Yes | |||
Condensate | Yes | |||
Water-glycol mixture (up to 40% by volume glycol content, from 10%, motor power adjustment is required) |
Yes | |||
Other low-viscosity liquids (without abrasive and long-fiber inclusions that destroy the pump) |
Yes | |||
Performance (at 50 Hz) | ||||
Max flow [m3/hour] | 5 | 8 | 12 | 25 |
Max. head [m] | 70 | 70 | 60 | 47 |
Pumped liquid temperature [aboutFROM] | from -15 to +110 | |||
Ambient temperature [aboutFROM] | 40 | |||
Working pressure [bar] | ten | |||
Inlet pressure [bar] | 6 | |||
Max. rotation speed [rpm] | 2950 | |||
Motor | ||||
Electrical connection 1~[V /Hz] (voltage tolerances ± 10%) |
230/50 or 220/60 | |||
Electrical connection 3~[V /Hz] (voltage tolerances ± 10%) |
230/50 ∆ or 220/60 ∆ 400/50 Y or 380/60 Y |
|||
Insulation class | F | |||
Interference | EN 61800-3 | |||
Degree of protection | IP 54 | |||
Accession | ||||
Connection diameter on the pressure side [Rp] | 1 | 1 | 1¼ | 1½ |
Materials | ||||
Working wheel | 1.4301 /1.4404 | |||
Step chambers | 1.4301 /1.4404 | |||
Pump housing | 1.4301 /1.4404 | |||
Shaft | 1.4404 | |||
Seals | EPDM (EP 851) /Viton | |||
case cover | 1.4301 /1.4404 | |||
Sliding mechanical seal | Graphite /Carbide tungsten | |||
Pressure shroud | 1.4301 /1.4404 | |||
Bearing | Wolfram carbide | |||
Pump base | Aluminum |
Explanations for inlet pressure: maximum pressure on inlet is calculated as the maximum operating pressure of the system minus the maximum pressure generated by the pump at Q=0.
Explanations for the materials used: steel 1.4301 complies with AISI 304, steel 1.4404 corresponds to AISI 316L.
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 22 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 22 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 33 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 33 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 45 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 45 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 56 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 56 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 68 |
Power capacity, kW | 1,5 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 8 |
Feed height, m | 68 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 1/4 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 22 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 22 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 33 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 33 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 45 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 45 |
Power capacity, kW | 0,55 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 56 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 56 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 68 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 5 |
Feed height, m | 68 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 24 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 24 |
Power capacity, kW | 0,75 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 36 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 36 |
Power capacity, kW | 1,1 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 48 |
Power capacity, kW | 1,5 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 12 |
Feed height, m | 60 |
Power capacity, kW | 2,2 |
Input pipe diameter | G1 1/2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 25 |
Feed height, m | 24 |
Power capacity, kW | 1,5 |
Input pipe diameter | G2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 25 |
Feed height, m | 36 |
Power capacity, kW | 2,2 |
Input pipe diameter | G2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 25 |
Feed height, m | 48 |
Power capacity, kW | 2,2 |
Input pipe diameter | G2 |
Producer | Wilo |
Pump capacity, cu.m/hour | 6 |
Power capacity, kW | 0,75 |
Power supply | 3х380 V, 50 Hz |
Max.flow rate, m3/h | 6 |