- EBARA PumpsEbara 1GP PEbara EVMS - EVMEbara 1GP HEbara 1GP PRESSCOMFORTEbara AGA-AGCEbara CDAEbara CM (A-B-C-D) - CMREbara compactEbara CVMEbara CVM with E-DRIVEEbara e-driveEbara EP SERIES (SD)Ebara IDROGOEbara JES-JEEbara JESX-JEXEbara lpsEbara MATRIXEbara MULTIGOEbara PRA-PRNEbara PRESSKOMFORTEbara SERIE 1EPRIGHT submersible sewage pumpEbara 3M Series Centrifugal PumpsCentrifugal surface pumps CDX, 2CDX
- Ebara EP SERIES (SD)
Ebara EP SERIES (SD)
Control and protection units for one, two or three electrical pumps (versions for 4 or more electric pumps can available on request). Manual or automatic operation modes using a pressure switch or float switch. Besides In addition, there are two clamps for connecting the float relay minimum level or minimum pressure switch for protection against dry running. When triggered, the electric pump stops with indication by means of corresponding indicators on the block management. Control units protect motors against overload and phase mismatch. Signals about any triggered protections go directly to the control unit, as well as to remote points using "dry" contacts (if a remote control unit is connected management). Overload and phase misalignment protection automatically resets three times, on the fourth actuation it resets performed manually (any first three triggers are reset one hour after the last activation).
Technical features
- P.MIN - protection against "dry running" (control by means of a float minimum pressure switch or switch) with automatic reset when water supply resumes;
- PR - control of starting and stopping the electric pump;
- Automatic change of the order of restarting in versions control unit for several electric pumps;
- Motor overload protection with automatic reset of three first trips and manual reset of the fourth trip;
- Protection against overload in case of short circuits by means of fusible fuses for starting the engine;
- Protection of transformer circuits and auxiliary equipment with fuses;
- Remote signaling by means of a potential-free contact;
- NC-NA triggered protections;
- Possibility to operate the unit including without the KL1 replacement module (only for 2EP SD units).
Technical data
- Power supply: 230 V 10-15%, 50/60 Hz (single phase);
- 230 V 10-15%, 50/60 Hz (three phases);
- Temperature: –10 °C to 40 °C;
- Protection class: IP55;
- Reference standards: EN 60204-1, EN 60439-1, EN 61000-6-3;
- EN 61000-6-1 (for domestic use).