- Home
- Industrial pumps
- Pumps by manufacturerACME POMPE - peristaltic pumps for pumping viscous liquidsAQUA - dosing pumps, controllers and analysers, dosing systemsBGS GENERAL - vacuum pumpsBTS ENGINEERING - Pumps for Water Supply, Wastewater Disposal, Firefighting, and Sewage SystemsCALPEDA - pumping equipment for heating, air conditioning, agricultureDAB - circulation pumps for heating and air conditioning systemsDEBEM - pumps for chemicals, foodstuffs, viscous productsEBARA - pumping equipmentEMEC - dosing pumps, integrated disinfection systems, controllers, sensorsETATRON - metering pumpsEUROAQUA - pumpsFLUIMAC - pumps for chemical liquidsGRUNDFOS - pumping equipmentGÜCÜM - vacuum pumping equipmentHYDRO-VACUUM - water ring vacuum pumps LIVERANI - screw, vortex, impeller, piston, gear pumps for pumping viscous liquidsM PUMPS - chemical pumps with magnetic driveNETTUNO - pumping systems for irrigation and wateringPEDROLLO - pumping equipmentQEEHUA - Chemical Pumps with Magnetic Coupling, Centrifugal, Self-Priming, Semi-Submersible PumpsROVATTI POMPE - pumps driven by a power take-off shaftROVER POMPE - pumps for pumping food liquids, juice, milk, emulsions, oil, wine, beer, wort, mashSAER - pumping equipmentSPERONI - pumping equipmentTECNICAPOMPE - pumping equipmentVENERONI - industrial pumps for watering, irrigation, lagoon mixersWILO – pumping equipment for water supply, wastewater disposal, circulation and pressure boostingYUY - sanitary pumps for viscous food products
- BTS ENGINEERING - Pumps for Water Supply, Wastewater Disposal, Firefighting, and Sewage SystemsWQ Submersible Drainage PumpsWQV, WQK submersible drainage pumps with cutting mechanismCDLF, BVS Series Multistage PumpsCDLF, BVS Series Multi-Stage Explosion-Proof PumpsBZ, SM series monoblock centrifugal pumps made of stainless steelDWO, BK, TS Series Monoblock Pumps with Open ImpellerJLM Series Circulation Pumps for Hot Water and Heating SystemsBT Series In-Line Circulation Pumps for Heating SystemsIHG, BGLH, BGWH Series Stainless Steel Dry Rotor PumpsIRG, BGL, BGW Series Cast Iron Dry Rotor PumpsGTP, BB, CSP Series Stainless Steel Monoblock Centrifugal PumpsJL Series Circulation Pumps for Heating
- WQ Submersible Drainage Pumps
WQ Submersible Drainage Pumps
Drainage pumps are used to pump clean or contaminated water from drainage wells, pits, pools and reservoirs. These pumps can be installed for permanent stationary operation or carried from place to place.
These pumps are of10 equipped with a float switch that starts and stops them in depending on the water level (in addition, modern models of leading pump manufacturers are supplied with protection against overheating and dry running). The portable WQ pumps are also designed for pumping water when underflooding, for use in engineering systems of agricultural and industrial enterprises and etc.
Description
Pumping process water free of solid particles and fibers.
Drainage pumps WQ - pumps are designed to pump drainage and groundwater from systems located in private residential buildings or backyards, in agricultural and small industrial enterprises, etc.
- Consumption: from 10 to 300 m³/hour.
- Head: from 7 to 35 m.
- Power: from 0.75 to 22 kW.
Characteristics
- The pumps are compact, do not create a lot of noise, do not consume a lot of energy, are available for main10ance and repair;
- The ability to provide control over the water level, electric current, overload and overheating of the engine;
- Depending on the level of runoff water, the level float switch can automatically turn on or off pump;
- The pump head is regulated until the maximum performance is reached, which does not harm the engine;
- There are two ways to install: installation with fixed connection and Mobile installation.
WQ50-10-4
200WQ300-15-22
Application
Drainage pumps are used in any wastewater treatment system that is required in municipal services, chemical plants, mines and quarries, cement production, etc.
- Pumping drainage and surface water;
- Groundwater pumping;
- Pumping process water free of solid particles and fibers.
Working conditions
Normal and long-term operation of the pump is ensured under the following conditions:
- The average temperature should not exceed + 40 °C;
- Average density of liquid that is pumped 1000 ... 1200 kg /m3;
- Frequency 50 Hz, voltage 380 V, permissible deviation of supply voltage within ± 5% of nominal.
Main settings

Performance charts

Drainage pumps WQ
| Model | Consumption (m3/hour) |
Head (m) |
Power (kw) |
Speed (rpm) |
Diameter (mm) |
Current (IN) |
Frequency (Hz) |
The weight (kg) |
| 50WQ10-10-0.75 | 10 | 10 | 0.75 | 2900 | 50 | 380 | 50 | 21 |
| 50WQ15-7-0.1 | 15 | 7 | 0.1 | 50 | 26 | |||
| 50WQ20-15-1.5 | 20 | 15 | 1.5 | 50 | 55 | |||
| 65WQ25-10-1.5 | 25 | 10 | 1.5 | 65 | 58 | |||
| 50WQ15-25-2.2 | 15 | 25 | 2.2 | 50 | 56 | |||
| 65WQ25-15-2.2 | 25 | 15 | 2.2 | 65 | 60 | |||
| 65WQ37-13-3 | 37 | 13 | 3 | 65 | 70 | |||
| 85WQ43-13-3 | 43 | 13 | 3 | 80 | 85 | |||
| 65WQ25-30-4 | 25 | 30 | 4 | 65 | 85 | |||
| 80WQ40-15-4 | 40 | 15 | 4 | 80 | 90 | |||
| 100WQ110-10-5.5 | 110 | 10 | 5.5 | 1450 | 100 | 155 | ||
| 100WQ100-15-7.5 | 100 | 15 | 7.5 | 100 | 170 | |||
| 100WQ100-25-11 | 100 | 25 | 11 | 100 | 65 | |||
| 200WQ300-7-11 | 300 | 7 | 11 | 200 | 73 | |||
| 100WQ100-30-15 | 100 | 30 | 15 | 100 | 300 | |||
| 150WQ180-15-15 | 180 | 15 | 15 | 150 | 280 | |||
| 200WQ250-15-15 | 250 | 15 | 15 | 200 | 400 | |||
| 100WQ100-35-18.5 | 100 | 35 | 18.5 | 100 | 380 | |||
| 150WQ180-20-18.5 | 180 | 20 | 18.5 | 150 | 400 | |||
| 200WQ250-15-18.5 | 250 | 15 | 18.5 | 200 | 500 | |||
| 150WQ180-25-22 | 180 | 25 | 22 | 150 | 430 | |||
| 200WQ300-15-22 | 300 | 15 | 22 | 200 | 550 |
Installation of the drainage pump WQ
Installation with fixed connection
Mobile installation
| Producer | BTS Engineering |
| Pump capacity, m3/h | 20 |
| Feed height, m | 15 |
| Power capacity, kW | 1,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Power capacity, kW | 11 |
| Material | cast iron |
| Output pipe diameter | DN50 |
| Rate of turn, rpm | 2 900 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 30 |
| Feed height, m | 60 |
| Power capacity, kW | 15 |
| Material | cast iron |
| Producer | BTS Engineering |
| Power capacity, kW | 5,5 |
| Output pipe diameter | DN100 |
| Rate of turn, rpm | 1 450 |
| Power supply | 3х380 V, 50 Hz |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 300 |
| Power capacity, kW | 22 |
| Material | cast iron |
| Output pipe diameter | DN200 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 25 |
| Feed height, m | 30 |
| Power capacity, kW | 5,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 30 |
| Feed height, m | 25 |
| Power capacity, kW | 4 |
| Output pipe diameter | DN80 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 80 |
| Feed height, m | 30 |
| Power capacity, kW | 15 |
| Output pipe diameter | DN100 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 100 |
| Feed height, m | 25 |
| Power capacity, kW | 11 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 15 |
| Feed height, m | 15 |
| Power capacity, kW | 2,2 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 180 |
| Feed height, m | 20 |
| Power capacity, kW | 18,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 250 |
| Feed height, m | 15 |
| Power capacity, kW | 22 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 40 |
| Feed height, m | 15 |
| Power capacity, kW | 4 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 25 |
| Feed height, m | 10 |
| Power capacity, kW | 2,2 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 25 |
| Feed height, m | 7 |
| Power capacity, kW | 1,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 35 |
| Feed height, m | 10 |
| Power capacity, kW | 3 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 70 |
| Feed height, m | 10 |
| Power capacity, kW | 5,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 180 |
| Feed height, m | 25 |
| Power capacity, kW | 22 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 250 |
| Power capacity, kW | 15 |
| Material | cast iron |
| Output pipe diameter | DN200 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 50 |
| Power capacity, kW | 4 |
| Material | cast iron |
| Output pipe diameter | DN100 |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 600 |
| Feed height, m | 12 |
| Power capacity, kW | 37 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 2200 |
| Feed height, m | 5 |
| Power capacity, kW | 55 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 1300 |
| Feed height, m | 31 |
| Power capacity, kW | 90 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 25 |
| Feed height, m | 18 |
| Power capacity, kW | 3 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 40 |
| Feed height, m | 28 |
| Power capacity, kW | 7,5 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 40 |
| Feed height, m | 18 |
| Power capacity, kW | 4 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 25 |
| Feed height, m | 17 |
| Power capacity, kW | 2,2 |
| Material | cast iron |
| Producer | BTS Engineering |
| Pump capacity, m3/h | 100 |
| Feed height, m | 15 |
| Power capacity, kW | 7,5 |
| Material | cast iron |