- Home
- Industrial pumps
- Pumps by manufacturer
- WILOWilo-Drain TSW stainless steel submersible pumpWilo-Drain TMW submersible pump for drainage water drainagePB booster pumpMVI vertical high pressure pumps HELIX FIRST, MVIHorizontal high pressure pumps MEDANA, MHIWell pumps Wilo-Sub TWI 5, TWI 5-SE, TWI 5-SE PNPWILO CronoNorm NL cantilever pumpsWilo-DrainLift KH, TMP Pressure plants for wastewater disposalPumping station Wilo-Jet HWJ with a hydraulic accuHigh pressure glandless pumps MVISSubmersible pumps Wilo-Drain MTS for wastewater diSelf-priming centrifugal pumps Wilo-Jet WJFire extinguishing system Wilo-SiFire ENSpecial IPH pumps for superheated water and thermal oilWilo-FLA-2 pressure boosting systemSewage pumps Wilo EMU FAWILO TOP-S Glandless Circulation PumpsCirculation pumps for heating systems and underflo
- Horizontal high pressure pumps MEDANA, MHI | page: 2
Horizontal high pressure pumps MEDANA, MHI | page: 2
Appointment
High pressure pumps WILO MHI are used for pumping drinking water, cold and hot water in heat and water supply systems, condensate, a mixture of water with glycol (up to 40% glycol in the mixture), as well as other media free of mineral fats, abrasive and long-fibred inclusions.
Application of high pressure pumps MHI: installation of water supply and raising pressure, boiler feed, industrial circulation systems, water cooling circuits, fire extinguishing systems, as well as washing and irrigation installations.
Diagram productivity
Designation
| Example:MHI 205N-1/E/3-400-50-2 | |
| MHI |
Horizontal multistage high-pressure centrifugal pump |
| 2 | Consumption in m³/h |
| 05 | Number of impellers |
| N | IE2 motor |
| 1 | Material 1=1.4301 (AISI 304) 2=1.4404 (AISI 316L) |
| E | Sealing type E=EPDM V=FKM (Viton) |
| 3 | 1=1 ~ (single phase current) 3=3 ~ (three-phase current) |
| 400 | Connectable voltage in V |
| 50 | Frequency in Hz |
| 2 | Number of poles |
Pumps increasing pressure series MHI
| Model | Power, kWt | Feed, m³/hour | Head, m | Picture |
| MHI 202 | 0.55 | 5 | 25 |
|
| MHI 203 | 0.55 | 5 | 35 | |
| MHI 204 | 0.55 | 5 | 45 | |
| MHI 205 | 0.75 | 5 | 55 | |
| MHI 206 | 1.1 | 5 | 65 | |
| MHI 402 | 0.55 | 8 | 25 | |
| MHI 403 | 0.55 | 8 | 35 | |
| MHI 404 | 0.75 | 8 | 45 | |
| MHI 405 | 1.1 | 8 | 55 | |
| MHI 406 | 1.5 | 8 | 70 | |
| MHI 802 | 0.75 | 12 | 25 | |
| MHI 803 | 1.1 | 12 | 35 | |
| MHI 804 | 1.5 | 12 | 45 | |
| MHI 805 | 1.85 | 12 | 60 | |
| MHI 1602 | 1.5 | 25 | 25 | |
| MHI 1603 | 1.85 | 25 | 35 | |
| MHI 1604 | 2.5 | 25 | 45 |
Technical data
| WILO MHI | ||||
| 2 ... | 4... | 8... | 16... | |
| Permissible pumped liquids | ||||
| Potable and industrial water, water systems heating | Yes | |||
| Condensate | Yes | |||
| Water-glycol mixture (up to 40% by volume glycol content, from 10%, motor power adjustment is required) |
Yes | |||
| Other low-viscosity liquids (without abrasive and long-fiber inclusions that destroy the pump) |
Yes | |||
| Performance (at 50 Hz) | ||||
| Max flow [m3/hour] | 5 | 8 | 12 | 25 |
| Max. head [m] | 70 | 70 | 60 | 47 |
| Pumped liquid temperature [aboutFROM] | from -15 to +110 | |||
| Ambient temperature [aboutFROM] | 40 | |||
| Working pressure [bar] | ten | |||
| Inlet pressure [bar] | 6 | |||
| Max. rotation speed [rpm] | 2950 | |||
| Motor | ||||
| Electrical connection 1~[V /Hz] (voltage tolerances ± 10%) |
230/50 or 220/60 | |||
| Electrical connection 3~[V /Hz] (voltage tolerances ± 10%) |
230/50 ∆ or 220/60 ∆ 400/50 Y or 380/60 Y |
|||
| Insulation class | F | |||
| Interference | EN 61800-3 | |||
| Degree of protection | IP 54 | |||
| Accession | ||||
| Connection diameter on the pressure side [Rp] | 1 | 1 | 1¼ | 1½ |
| Materials | ||||
| Working wheel | 1.4301 /1.4404 | |||
| Step chambers | 1.4301 /1.4404 | |||
| Pump housing | 1.4301 /1.4404 | |||
| Shaft | 1.4404 | |||
| Seals | EPDM (EP 851) /Viton | |||
| case cover | 1.4301 /1.4404 | |||
| Sliding mechanical seal | Graphite /Carbide tungsten | |||
| Pressure shroud | 1.4301 /1.4404 | |||
| Bearing | Wolfram carbide | |||
| Pump base | Aluminum | |||
Explanations for inlet pressure: maximum pressure on inlet is calculated as the maximum operating pressure of the system minus the maximum pressure generated by the pump at Q=0.
Explanations for the materials used: steel 1.4301 complies with AISI 304, steel 1.4404 corresponds to AISI 316L.

| Producer | Wilo |
| Pump capacity, m3/h | 6 |
| Power capacity, kW | 0,75 |
| Power supply | 3х380 V, 50 Hz |
| Max.flow rate, m3/h | 6 |
| Producer | Wilo |
| Power capacity, kW | 1,5 |
| Input pipe diameter | G 1 1/4" |
| Output pipe diameter | G 1" |
| Rate of turn, rpm | 2900 |
| Producer | Wilo |
| Pump capacity, m3/h | 3.9 |
| Feed height, m | 62 |
| Power capacity, kW | 0,75 |
| Material | AISI 304 stainless steel |
| Producer | Wilo |
| Pump capacity, m3/h | 3.9 |
| Feed height, m | 62 |
| Power capacity, kW | 0,75 |
| Input pipe diameter | G 1" |
| Producer | Wilo |
| Pump capacity, m3/h | 6.4 |
| Feed height, m | 64 |
| Power capacity, kW | 1,1 |
| Input pipe diameter | G 1" |
| Producer | Wilo |
| Pump capacity, m3/h | 15.4 |
| Feed height, m | 23.5 |
| Power capacity, kW | 1,1 |
| Input pipe diameter | G 1 1/2" |