- WILOWilo-Drain TSW stainless steel submersible pumpWilo-Drain TMW submersible pump for drainage water drainagePB booster pumpMVI vertical high pressure pumps HELIX FIRST, MVIHorizontal high pressure pumps MEDANA, MHIWell pumps Wilo-Sub TWI 5, TWI 5-SE, TWI 5-SE PNPWILO CronoNorm NL cantilever pumpsWilo-DrainLift KH, TMP Pressure plants for wastewater disposalPumping station Wilo-Jet HWJ with a hydraulic accuHigh pressure glandless pumps MVISSubmersible pumps Wilo-Drain MTS for wastewater diSelf-priming centrifugal pumps Wilo-Jet WJFire extinguishing system Wilo-SiFire ENSpecial IPH pumps for superheated water and thermal oilWilo-FLA-2 pressure boosting systemSewage pumps Wilo EMU FAWILO TOP-S Glandless Circulation PumpsCirculation pumps for heating systems and underflo
- MVI vertical high pressure pumps HELIX FIRST, MVI | page: 6
MVI vertical high pressure pumps HELIX FIRST, MVI | page: 6

Specifications
- stainless steel direct flow pump in-line execution;
- standard three-phase motor V18 /V1;
- temperature of the pumped medium: -15 °C to + 120 °C;
- Max. working pressure: 16 bar and 25 bar;
- optional steel quality: 1.4301 or 1.4404;
- scope of delivery includes oval counter flanges (from Rp 1 to Rp 1 1/2) for PN16 version.
Description
Wilo Multivert MVI - booster, non-self-priming, vertical centrifugal pump in-line constructions. Impellers, as well as all parts in contact with the pumped medium, are made of chrome-nickel steel. Direction of rotation independent, mechanical seal. Shafts of the motor and pump connected by a longitudinal spherical coupling. The rolling bearing in the lantern fully compensates axial hydraulic forces.
Standard three-phase or single-phase motor (max. Up to 1.5 kW), version V1 or V18. For motors three-phase current protection is required, single-phase current motors are equipped with built-in protection and capacitor. KTW /WRC approval for all plastic parts used. PN 16 design with oval flange and GG counter flange. Round flanges in PN 25 design.
Symbols
Example: Wilo MVI 405
- MVI - multistage, vertical, centrifugal pump with flange connection motor; all parts in contact with the medium made of INOX (stainless steel 1.4301);
- 4 - nominal flow rate in m³/hour (2 pole /50 Hz);
- 05- number of steps.
Application
- water supply and pressure boosting;
- fire extinguishing systems;
- make-up;
- industrial circulation systems;
- technological processes;
- cooling systems;
- washing and watering machines.
Indicators at 50 Hz | MVI 1 | MVI 2 | MVI 4 | MVI 8 | MVI 16 ..- 6 |
Max. innings, m³ /hour | 3 | four | 8 | 16 | 25 |
Max. pressure, m | 240 | 230 | 210 | 230 | 130 |
|
|||||
Indicators at 50 Hz | MVI 16 | MVI 32 | MVI 52 | MVI 70 | MVI 95 |
Max. innings, m³/hour | 25 | fifty | 70 | one hundred | 150 |
Max. pressure, m | 240 | 220 | 180 | 172 | 160 |
Performance characteristics Wilo-Multivert MVI 1/2/4/8/16 ..- 6

Performance characteristics Wilo-Multivert MVI 32/52/70/95

Producer | Wilo |
Pump capacity, cu.m/hour | 35 |
Feed height, m | 35 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 35 |
Feed height, m | 55 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 35 |
Feed height, m | 82 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 35 |
Feed height, m | 90 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 35 |
Feed height, m | 110 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 34 |
Feed height, m | 125 |
Input pipe diameter | DN 50 |
Output pipe diameter | DN 50 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 25 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 50 |
Feed height, m | 18 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 50 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 50 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 37 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 75 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 70 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 64 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 100 |
Input pipe diameter | DN 65 |
Output pipe diameter | DN 65 |
Producer | Wilo |
Pump capacity, cu.m/hour | 80 |
Feed height, m | 28 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 70 |
Feed height, m | 18 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 80 |
Feed height, m | 56 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 80 |
Feed height, m | 38 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 80 |
Feed height, m | 85 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 80 |
Feed height, m | 65 |
Input pipe diameter | DN 80 |
Output pipe diameter | DN 80 |
Producer | Wilo |
Pump capacity, cu.m/hour | 55 |
Feed height, m | 37 |
Power capacity, kW | 4 |
Material | AISI 304 stainless steel |